ADT-LCD40 Series
Remote Fire
Annunciators
for use with Unimode 200
Addressable Fire Alarm Control Panel
Ack Silence
Reset
Drill
Hold 2 sec.
FIRE ALARM ANNUNCIATOR
Document #50520
7/25/00 Rev:
D
P/N 50520:D ECN 00-325
ADT Security Services, Inc.
One Town Center Road
Boca Raton, FL 33431
Phone: (561) 988-3600
FAX: (561) 988-3675
Page view 0
1 2 3 4 5 6 ... 35 36

Summary of Contents

Page 1 - Annunciators

ADT-LCD40 SeriesRemote Fire Annunciatorsfor use with Unimode 200 Addressable Fire Alarm Control Panel Ack SilenceResetDrillHold 2 sec.FIRE ALARM ANNUN

Page 2 - Fire Alarm System Limitations

ADT-LCD40 Series Annunciators SW1 DIP Switch Settings10Document 50520 Rev D 7/25/00 P/N 50520:D1.3 SW1 DIP Switch SettingsThe Up position on DI

Page 3 - Installation Precautions

ADT-LCD40 Series Annunciators DIP Switch Settings Example11Document 50520 Rev D 7/25/00 P/N 50520:D.Note: SW1 DIP switch settings as illustrate

Page 4

ADT-LCD40 Series Annunciators Typical Configuration12Document 50520 Rev D 7/25/00 P/N 50520:D1.4 Typical ConfigurationThe ADT-LCD40 Series Annu

Page 5 - Table of Contents

Operation Display Patterns13Document 50520 Rev D 7/25/00 P/N 50520:DSection 2: Operation2.1 Display PatternsThe ADT-LCD40 Series Annun

Page 6 - ADT-LCD40 Series Annunciators

Operation Switch Functions for ADT-LCD40 Only14Document 50520 Rev D 7/25/00 P/N 50520:D2.2 Switch Functions for ADT-LCD40 Only2.2.1 Key-switch

Page 7 - 1.2 ADT-LCD40 Only

Operation Switch Functions for ADT-LCD40 Only15Document 50520 Rev D 7/25/00 P/N 50520:DLEDs to steady on. The second press of the switch stops

Page 8 - Figure 1-1: Components

Operation LED Indicators (all ADT-LCD40 Series)16Document 50520 Rev D 7/25/00 P/N 50520:D2.3 LED Indicators (all ADT-LCD40 Series)2.3.1 PowerTh

Page 9

Mounting ADT-LCD40 Series Preparation17Document 50520 Rev D 7/25/00 P/N 50520:DSection 3: Mounting3.1 ADT-LCD40 Series PreparationThe

Page 10 - 1.3 SW1 DIP Switch Settings

Mounting Hardware and Backboxes18Document 50520 Rev D 7/25/00 P/N 50520:DAck SilenceResetDrillHo ld 2 sec.FIRE ALARM ANNUNCIATORFigure 3-2: Har

Page 11 - Down Position = On State

Mounting Semi-flush Mount Backbox19Document 50520 Rev D 7/25/00 P/N 50520:D3.2 Semi-flush Mount BackboxRemove the plug-in terminal blocks from

Page 12 - 1.4 Typical Configuration

LimWarSm.p65 01/10/2000An automatic fire alarm system–typically made up ofsmoke detectors, heat detectors, manual pull stations,audible warning dev

Page 13 - Operation

Mounting Surface Mount Backbox20Document 50520 Rev D 7/25/00 P/N 50520:D3.3 Surface Mount BackboxRemove the plug-in terminal blocks from the AD

Page 14

ADT-LCD40 Series Electrical Connections Power Connection21Document 50520 Rev D 7/25/00 P/N 50520:DSection 4: ADT-LCD40 Series Electric

Page 15

ADT-LCD40 Series Electrical Connections EIA-485 Connection22Document 50520 Rev D 7/25/00 P/N 50520:DNotes:1. All connections are power-limited

Page 16

ADT-LCD40 Series Electrical Connections DIM-485 Connections23Document 50520 Rev D 7/25/00 P/N 50520:D1. Terminal to terminal wiring is shown be

Page 17 - Mounting

ADT-LCD40 Series Electrical Connections Wiring FACP to ADT-LCD40 Series24Document 50520 Rev D 7/25/00 P/N 50520:DDim-485 Installation. CAUTION!

Page 18 - FIRE ALARM ANNUNCIATOR

EIA-485 Shield Termination EIA-485 Shield Not in Conduit25Document 50520 Rev D 7/25/00 P/N 50520:DSection 5: EIA-485 Shield Terminatio

Page 19

EIA-485 Shield Termination EIA-485 Without Conduit26Document 50520 Rev D 7/25/00 P/N 50520:DFigure 5-1: EIA-485 Without ConduitConnect the drai

Page 20 - Figure 3-4: Surface Mounting

EIA-485 Shield Termination EIA-485 Shield in Full Conduit27Document 50520 Rev D 7/25/00 P/N 50520:D5.2 EIA-485 Shield in Full ConduitThe EIA-48

Page 21 - Connections

Programming the Unimode 200 EIA-485 In Conduit28Document 50520 Rev D 7/25/00 P/N 50520:DSection 6: Programming the Unimode 200The Unim

Page 22

29Document 50520 Rev D 7/25/00 P/N 50520:DAAcknowledge switch 6, 7, 12, 14ADT-LCD40 6, 7, 10, 14, 15see also ADT-LCD40 Series Annunciatorssoftw

Page 23 - 1 2 3 4

LimWarSm.p65 01/10/2000WARNING - Several different sources of power can beconnected to the fire alarm control panel. Disconnect allsources of powe

Page 24

30Document 50520 Rev D 7/25/00 P/N 50520:Dwiring 23DIM-485 module 7DIP Switch settings 8, 10, 11function switches 11piezo sounder 11Receive/Tra

Page 25 - EIA-485 Shield Termination

31Document 50520 Rev D 7/25/00 P/N 50520:DLiquid Crystal Display 6Local Authority Having Jurisdiction 8, 10MManual Evacuate 15mounting 7, 17, 1

Page 26

32Document 50520 Rev D 7/25/00 P/N 50520:DSilence switch 6, 14, 15software versionADT-LCD40 6Unimode 200 6static 25static protection 17supervis

Page 27

33Document 50520 Rev D 7/25/00 P/N 50520:DNotes

Page 28 - Programming the Unimode 200

34Document 50520 Rev D 7/25/00 P/N 50520:DNotes

Page 29

35Document 50520 Rev D 7/25/00 P/N 50520:DNotes

Page 31

4Document 50520 Rev D 7/25/00 P/N 50520:DNotes

Page 32

Table of Contents5Document 50520 Rev D 7/25/00 P/N 50520:DTable of ContentsSection 1: ADT-LCD40 Series Annunciators ...

Page 33

ADT-LCD40 Series Annunciators6Document 50520 Rev D 7/25/00 P/N 50520:DSection 1:ADT-LCD40 Series AnnunciatorsNote: Only Model ADT-LCD40L is lis

Page 34

ADT-LCD40 Series Annunciators ADT-LCD40 and ADT-LCD40L7Document 50520 Rev D 7/25/00 P/N 50520:D1.1 ADT-LCD40 and ADT-LCD40L• 40-character LCD d

Page 35

ADT-LCD40 Series Annunciators Components8Document 50520 Rev D 7/25/00 P/N 50520:DFigure 1-1: ComponentsFuture useON = Piezo EnableOFF = Key-swi

Page 36

ADT-LCD40 Series Annunciators Wiring to Terminals9Document 50520 Rev D 7/25/00 P/N 50520:D Figure 1-2: Wiring to TerminalsTerminal Block replac

Comments to this Manuals

No comments